Home/Guides/Loft insulation: how thick, and how many rolls?
Walls & Finishes · 3 min read

Loft insulation: how thick, and how many rolls?

Why 270 mm is the target, how to top up existing insulation, and what it does to the U-value.

Insulation is one of the cheapest upgrades for energy savings, and one of the easiest to under-order. The quantity depends on two things: the area to cover, and the depth or performance you're aiming for. Get the target right first, then the material count is simple.

Why 270 mm?

For mineral wool in a loft, 270 mm is the widely recommended depth and gives an insulation U-value of around 0.16 W/m²K. Many older lofts have 100 mm or less, which loses far more heat. Building Regulations for new work set U-value targets rather than thicknesses, and those targets have tightened over time.

Two layers, crossed

The first layer goes between the joists, usually 100 mm to match the joist depth. The top-up layer, often 170 mm, goes across the joists at right angles. This covers the joists themselves, which would otherwise be cold bridges, and closes any gaps in the first layer.

Counting rolls

Rolls = layers × loft area ÷ coverage per roll. Coverage depends on thickness: roughly 8.3 m² for 100 mm, about 6 m² for 150–170 mm and about 5.6 m² for 200 mm. Check the pack, as products vary. Allow 5% for cutting around joists, pipes and hatches.

Topping up

Measure the existing depth in several places. If it's patchy, compressed or damp, it may be better to remove it. Otherwise, top up to the target with one or two layers laid across the joists.

Things that go wrong

  • Blocking eaves ventilation. Fit rafter trays or eaves carriers first, so air can flow from the eaves.
  • Squashing insulation under boards. Compressed insulation loses much of its value. Raise storage boards on legs.
  • Covering recessed lights that aren't rated for contact with insulation.
  • Forgetting the loft hatch: insulate and draught-seal it too.
  • Leaving water pipes and tanks above the insulation unprotected. Once the loft is colder, they can freeze.
  • Not sealing air leaks first. Gaps around pipes, cables and light fittings let warm, moist air into the cold space.

Walls and floors

Cavity walls can often be filled by an approved installer. Solid walls need internal or external insulation, which is a bigger job with planning, damp and detailing issues. Suspended timber floors can be insulated from below between the joists. Each of these has its own detailing, so treat them as separate items on the quote.

Safety and access

Wear gloves, long sleeves, eye protection and a dust mask. Work from boards across the joists, never on the ceiling between them, and keep good lighting. Check for old wiring before covering it, and keep insulation clear of chimneys and flues.

A worked example

A 48 m² loft with 100 mm existing, topped up to 270 mm with one layer of 170 mm rolls at 6 m² per roll: 48 × 1.05 ÷ 6 = 8.4, so 9 rolls.

The insulation calculator works out rolls and layers to reach your target depth, with an approximate U-value.

Common questions

Can I put too much insulation in a loft?

Not in terms of heat loss, but you must keep the ventilation paths at the eaves open, and leave access to junction boxes, water tanks and hatches.

Does insulation need a vapour barrier?

In lofts, the key is good ventilation above the insulation and sealing air leaks from the rooms below. On walls, a vapour control layer on the warm side is often required. Follow the manufacturer's details and Building Regulations.

Pricing the job

Materials are only part of the price. Clearing stored items out of the loft, fitting eaves trays, moving or protecting cables, insulating pipes and tanks, boarding for storage, and disposing of old insulation all take time. List them separately, so the client can see what they're paying for and decide on the optional items.

This guide is general information for estimating. It is not engineering, legal or tax advice. Check the Building Regulations and Building Control for your project.