How it’s calculated

Layout studs = (wall length ÷ spacing) + 1. Each corner or junction adds 2 studs, and each opening adds 3 for kings, jacks and cripples (cripples usually come from offcuts). The plate run is the wall length × the number of plate rows.

Worked example

With these inputs:

Wall length
4.8 m
Wall height
2.4 m
Spacing (on centre)
400 mm centres
Stud size
38 × 89 mm CLS
Corners and wall junctions
2
Door and window openings
1
Double top plate
No
Include sheathing / boarding one side
No
Sheathing sheet size
2440 × 1220 mm
Waste allowance
10%

the result is:

Studs needed
22 studs
Studs on layout
13
Extra at corners & openings
7
Stud length (wall − plates)
2.32 m
Plate run (2 rows)
9.6 lin m

Tips from the trade

  • Headers over openings are sized from span tables or by your engineer. Add them as separate items.
  • In the UK, partition walls are often CLS 38 × 89 at 400 or 600 mm to suit plasterboard widths.
  • Mark your layout from the same end on every wall so studs line up for sheathing joints.

Common questions

How many studs do I need per metre of wall?

At 400 mm centres, roughly 3 studs per metre of wall once you include corners and openings.