TakeoffYard
Home/Guides/Stair rules: Approved Document K basics
Stairs, Ramps & Rails · 4 min read

Stair rules: Approved Document K basics

Rise, going, pitch, headroom and guarding for private stairs in England, and how to lay out a compliant flight.

Stairs are among the most inspected parts of any job, and among the most dangerous when they're wrong. Small inconsistencies trip people, because we stop looking at our feet after the first step or two. These are the core rules for private stairs in dwellings under Approved Document K (England). Always confirm with Building Control, since Wales, Scotland and Northern Ireland have their own regulations.

The key dimensions

ItemRule
Rise220 mm maximum
Going220 mm minimum
Pitch42° maximum
2R + G550–700 mm
Headroom2.0 m (1.9 m on the centreline for loft conversions, sloping to 1.8 m at the side)
Handrail height900–1000 mm
Guarding openings100 mm sphere must not pass
Open risersOverlap treads by at least 16 mm, and openings under 100 mm

Laying out a flight

Floor or ceiling above Pitch line Headroom 2.0 m min Rise 220 mm max Going 220 mm min Total rise floor to floor Total going
Every rise in a flight should match, and so should every going. Measure the total rise between finished floors, then divide it into equal steps.
  1. Measure the total rise from finished floor to finished floor. Allow for floor finishes at both ends: carpet, tile and screed all change it.
  2. Divide by the maximum riser and round up to get the number of risers.
  3. Divide the total rise by that number for the exact riser height.
  4. Treads = risers − 1. Total run = treads × tread depth.
  5. Check the total run fits the space, and check headroom along the whole flight against the floor or ceiling above.
  6. Work out the stringer length and the angle, then mark out a pattern stringer.

A comfortable private stair often lands around 190–200 mm rise and 240–250 mm going, giving a 2R + G of about 630–650 mm. The steeper the stair, the more it saves space but the harder it is to use, especially for children and older people.

Winders and landings

Winders (tapered treads that turn a corner) save space but need care. Approved Document K sets the going for tapered treads at the centre of the stair, with a minimum of 50 mm at the narrow end. Landings at the top and bottom need to be at least as wide and as deep as the stair, and clear of door swings.

Handrails and guards

A handrail is required on at least one side if the stair is under 1 m wide, and on both sides if wider. Guarding is required on open sides where there's a drop of more than 600 mm. Guards must resist a set load, so fix posts and balusters properly, not just with nails into the trim.

Common failures

  • The top or bottom riser is a different height because the floor finish wasn't allowed for.
  • Headroom too low under a beam or at the edge of the stair opening.
  • Spindles spaced just over the 100 mm limit.
  • A missing handrail where one is required, or handrails that stop short of the last riser.
  • Nosings missing or inconsistent, which changes the effective going.
  • Gaps under open risers that a child could slip through.

External steps and decks

The same principles apply outside, and consistency matters even more on wet, uneven ground. Make every step the same, give treads a slight fall so water runs off, and add lighting for steps used after dark.

Pricing stairs

Stairs take far longer per material dollar than most carpentry. Allow time for setting out, cutting a pattern stringer, test fits, and the finish work on treads, nosings and handrails. A stair that's "nearly right" has to be rebuilt, so price enough time to get it right first.

The stair calculator runs these checks as you type, the spindle calculator spaces guards to the limit, and the ramp calculator covers access ramps.

A worked example

A floor-to-floor height of 2600 mm. 2600 ÷ 220 = 11.8, so 12 risers at 216.7 mm. That gives 11 treads; with a 250 mm going, the total run is 2.75 m. 2R + G = 683 mm and the pitch is about 41°, both just within the rules. A 900 mm wide stair takes three stringers.

Common questions

Can I build a steeper stair to save space?

Only within the limits above, except for alternating-tread or paddle stairs, which are allowed in loft conversions to a single habitable room where there isn't space for a normal stair.

Do deck and porch stairs follow the same rules?

Yes, where they form part of the building. External steps to a house should follow the same rise and going limits for comfort and safety, and steps that form part of an access route to the entrance also have to meet Approved Document M.

Are open risers allowed?

Yes, but treads must overlap by at least 16 mm, and the gap between treads must not let a 100 mm sphere pass. A riser bar or a deeper tread closes the gap.

When do I need handrails on both sides?

For a private stair, a handrail is needed on at least one side if the stair is under 1 m wide, and on both sides if it is 1 m or wider. Set the top 900–1,000 mm above the pitch line, and carry it on past the top and bottom steps where you can.

What are the limits for a loft conversion stair?

The normal private stair rules apply: rise up to 220 mm, going at least 220 mm and a pitch no steeper than 42°. Headroom can drop to 1.9 m at the centre of the stair, and 1.8 m at the side, where the roof slope makes 2.0 m impossible.

Before you build

Mark out the stair at full size on the floor or a wall, including the floor finishes, to check headroom and landing space. Confirm the design with the inspector before cutting, especially for winders, open risers and loft conversions.

This guide is general information for estimating. It is not engineering, legal or tax advice. Check the Building Regulations and Building Control for your project.

More guides